DESCRIPTION
DYNA® PS-1 Penetrating Sealant is a clear and transparent sealer formulated to protect interlocking pavers, concrete surfaces, cementitious surfaces, their joints, masonry brick, and stucco against stains, dust, dirt, water, acid rain, chemical attack, fungus, salts, UV rays, and efflorescence damage. PS-1 also protects from freeze/thaw damage such as spalling and bubbling rendered by the harshest climates. Treated surfaces develop hydrophobic properties. Non-film forming and will not make surface slippery. Surfaces that are treated with this product absorb significantly less and yet the surface develops no change in moisture vapor transmission.
FEATURES & ADVANTAGES

- Non-film-forming invisible finish
- Protects against spalling, freeze/thaw damage, chemical attack, salt, biological growth, efflorescence, tar, and dirt pickup
- Does not change the appearance of the surface being treated
- Chemically and physically bonds to surface
- Has excellent depth penetration
- UV stable
- Will not peel or yellow
- Vapour permeable
RECOMMENDED SURFACES
For interior and exterior uses (UV stable), it can be applied on colored porous concrete surfaces such as:
- Interlocking Concrete Pavers
- Stamped Concrete
- Cementitious Surfaces
- Terrazzo Floors
- Masonry Brick
- Stucco
- Grout Joints
SECTIONS - 070000 / 071900 / 071923 / 096100 |
DIRECTIONS
A. SURFACE TESTING
Before starting your project, always perform a surface test by applying the product on a small inconspicuous area and let the surface dry for 60 minutes. If you are satisfied with the results, proceed with the work.
B. SURFACE PREPARATION
1. Remove all stains with the adequate DYNA® Cleaning Solutions.
2. Clean the entire surface area using DYNA® EF Efflorescence Cleaner. This step is necessary in order to remove efflorescence deposits, ground in dirt and color variations. Let dry completely.
3. Let dry completely after cleaning. It is recommended to wait at least 24 hours without dampness before applying the PS-1 Penetrating Sealant. However, if pavers have been exposed to full day sun for 6 hours after cleaning, you can proceed with the application.
C. SEALANT APPLICATION
CONDITIONS
When applying PS-1 Penetrating Sealant, the ideal temperature should be between 18°C (65°F) and 25°C (77°F) with no rain in the forecast for the next 12 hours. The surface to be treated should be completely dry, clean and even looking. Morning application is recommended.
(Application under scorching sun is not recommended)
TOOLS
Use a slit foam roller and a metal paint tray. If you wish to use a sprayer to apply the PS-1 Penetrating Sealant, make sure that you back roll the surface immediately with the slit foam roller to even out the
surface.
METHOD
HORIZONTAL APPLICATION
Starting at the highest point of the surface, proceed in small sections of 2 m x 2 m (7 ft x 7 ft) at a time. Using the slit foam roller, roll on one coat of PS-1 Penetrating Sealant followed by an immediate second coat to saturate the surface being treated. Redistribute any puddles or free standing sealant. Proceed to your next area.
VERTICAL APPLICATION
Starting at the highest point of the surface, proceed in small sections of 2 m x 2 m (7 ft x 7 ft) at a time. Using the slit foam roller, roll on ONLY ONE generous coat of PS-1 Penetrating Sealant to saturate the surface being treated. Roll out any running sealant to prevent streaking. Proceed to your next area.
When reaching the bottom, clean up all excess sealant at the base to prevent puddling.
CAUTION
1. For newly installed surfaces, wait at least 60 days before using this product.
2. Do not apply if surface is damp or dirty.
3. Do not apply if weather is uncertain.
4. Do not apply in extreme heat. (Mid-day sun).
CLEAN-UP
Clean all tools with lacquer or paint thinner.
PACKAGING
DYNA® PS-1 Penetrating Sealant is available in 3.78 L (1 US gallon), 18.9 L (5 US gallons).
COVERAGE
25 to 30 square meters (275 to 325 square feet) per 3.78 L (1 gallon) depending on the surface treated.
128 to 150 square meters (1375 to 1625 square feet) per 18.9 L (5 gallons) depending on the surface treated.
STORAGE
Keep in storage at temperature between 10°C (50°F) and 22°C (72°F). The shelf life of this product is 5 years in its original unopened container.
SHIPPING INFORMATION
Ground and Maritime freight : Not Regulated
Packing Group : III
SAFETY WARNINGSCAUTION WARNING |
NOTICEDYNA shall not be liable for incidental and consequential damages, indirectly or directly sustained, nor for any loss by application of these goods not in accordance with the printed instructions or for other than the intended use. Before using the user shall determine the suitability of the product for its intended use and the user will assume all risks and liabilities that may arise in connection therewith. DYNA’s liability is expressly limited to the replacement of defective goods. Any claim shall be deemed waived unless the claim is made in writing to DYNA within 15 days |
FIRST AID TREATMENT
Contains light aromatic hydrocarbon, methyl methacrylate. If swallowed, call Poison Control Center or doctor immediately. If person is alert, induce vomiting. If in eyes, rinse well with water for 15 minutes. If on skin, wash with soap and water for 15 minutes. If on clothes, remove clothes. If breathed in, move person into fresh air. If unsure of condition, get medical attention immediately.
LIMITED WARRANTY
This premium quality product was designed to satisfy the user. If you are not satisfied after Surface Testing on a small area, please contact our technical service department immediately.
NO WARRANTIES expressed or implied are offered by DYNA. The Manufacturer’s liability is limited to the replacement of products proven defective.
The user assumes all risks and liabilities associated with the use of this product.

The coverage for DYNA® PS-1 Penetrating Sealant is as follows:
Product Performance |
---|
Test Procedure | Typical Values Obtained |
---|---|
Physical State | Liquid |
Colour | Translucent clear and mobile liquid |
Odour and Appearance | Sweet / acetic |
Water Solubility | Negligible |
Specific Gravity | .83642 |
Boiling Point | 195°C |
Freezing Point | Not applicable |
Flash Point | > 212°F (> 100°C) ASTM D 3278 |
Melting Point | Not applicable |
Percent Volatile | 60 - 90% |
ASTM C 97 Reduction of Under Absorption (compared to untreated surface) |
90% |
ASTM E 96 Water Vapour Transmission (retention compared to untreated control) |
91% |
ASTM E 514 Standard Test Method for
Water Penetration and Leakage Through Masonry (compared to untreated control) |
100% |
Partition Coefficient (K o/w) | No data available |
Evaporation Rate | .12 n-butyl acetate = 1 |
Viscosity | Unknown |
VOC | < 349 g/L |

TECHNICAL SUPPORT